Across International 10C to 25C 33L/Min 17L Capacity Recirculating Chiller, 110 Volt

$150.00 $4,690.00
available: In Stock

Ai WAC-1 digital temperature controlled recirculating water chiller with built-in swivel casters, recommended for our IH series induction heaters (see models below). These chillers have built-in stainless steel tank and water pump for durability and rust-f


Payment: Payment Option Image

SKU: Q842205265 Category:

Ai WAC-1 digital temperature controlled recirculating water chiller with built-in swivel casters, recommended for our IH series induction heaters (see models below). These chillers have built-in stainless steel tank and water pump for durability and rust-free operation. two sets of water manifolds included for immediate use.

What’s Included

  • WAC-1 recirculating chiller
  • (2x) Water manifold
  • (2x) KF40 clamp
  • User’s manual

Specs

Model
WAC-1
Input power 110 VAC 60 Hz single-phase (1PH) 1460 watts
Nominal cooling capacity 1935 kcal/h
Nominal cooling capacity is according to:
Inlet chilled fluid temperature: 12C
Outlet chilled fluid temperature: 7C
Inlet cooling air temperature: 30C
Outlet cooling air temperature: 35C
Compressor Make: Panasonic , UL Listed
Power: 110VAC 60Hz 1-PH, LRA42, thermally protected
Refrigerant: R410A (800g)
Number of compressor installed: one
Water pump Make: LX (CMFL2-20-A-W-G-BABE)
Power: 110VAC 60Hz 1-PH 370 watts 3.7A 3450 rpm IP55
Flow rate: 528 gallons per hour
Max pressure: 10 bar. H(max); 20.5m, H(n): 16m
Reservoir volume 4.5 gallons
Cooling fan Make: Kunli (YWF A2S-300S-5DIIIA05)
Power: 110VAC 60Hz 1-PH 155 watts 1.35A 2700rpm 16uF/500V IP44
Flow rate: 70,000 cu ft per hour
Number of fan installed: one
Temperature accuracy +/- 2 C
Recommended coolant Distilled water
Water inlet & outlet on chiller
KF40 flange
Manifold Inlet: KF40, outlet: 8mm quick connect with ball valve
Unit/shipping weight 200 Lb / 260 Lb
Unit/shipping dimensions 29 x 17 x 35″ / 36 x 21 x 42″ (DxWxH)
Safety Over current and c ompressor thermal protection
Working environment Temperature range of chilled fluid: 5C – 35C
Temperature difference of chilled fluid between inlet
and outlet: 3C – 8C. It is better to use the chiller while
the ambient temperature at or below 35C

Compatiable Ai induction heaters High frequency 4kW, 6.6kW
Mid frequency 15kW, 25kW
Low frequency 15kW
CE compliant Yes

Reviews

There are no reviews yet.

Be the first to review “Across International 10C to 25C 33L/Min 17L Capacity Recirculating Chiller, 110 Volt”

Your email address will not be published. Required fields are marked *